Abstract:
An experimental study has been performed to investigate the in-plane strength of
masonry infilled reinforced concrete frame retrofitted with ferrocement. A half scale
masonry infill panel was constructed and tested in the laboratory for this purpose.
The load was applied monotonically at the top of the frame till the ultimate capacity
was reached accompanied by substantial formation and propagation of cracks. Then
both the infill and the frame was repaired by ferrocement coating. After
rehabilitation, the frame was tested in the laboratory following the same procedure as
for the original frame. The masonry infill frame retrofitted with ferrocement showed
significant improvement in performance and more than original strength was
achieved. This reveals the potential use of ferrocement as a retrofitting material of
existing infilled frame.