DSpace Repository

Inspection, safety and health concerns and practices titas gas transmission and distribution company limited

Show simple item record

dc.contributor.advisor Rahman, Dr. Mohammed Muhbubur
dc.contributor.author Siddiqur Rahman, Md.
dc.date.accessioned 2015-12-07T12:48:04Z
dc.date.available 2015-12-07T12:48:04Z
dc.date.issued 2007-12
dc.identifier.uri http://lib.buet.ac.bd:8080/xmlui/handle/123456789/1480
dc.description.abstract Safety is the top most priority in Titas Gas Transmission and Distribution Company Limited (TGTDCL) which ensures unintenupted supply of natural gas (NG) in greater Dhaka, Mymenshing and Brammanbaria. It is related to the health and environment. Unsafe pipeline b "eD' dangerous for personal, equipment & material, property and environment. To ensure safety, regular inspection of gas pipelines should always be canied out by trained manpO\\ier and sometimes along with concerned special authorities to meet the demand of national safety standard and regulations. Physical inspection. continuous s~les & purchase monitoring, regular patrolling system are essential for maintaining safety of transmission pipelines. Private ~ec,lJity service has been engaged for safety of high pressure pipelines and regular supervision also pre, ent accidents. The tusk of replacing the old pipeline by phases has also been taken up to improve safety mea,ures and avoid operational hazards. Program for health and environmental sJfety improvement has also been taken up. Inspection for safety in pipeline cOllstructionphase is given top most priority TGIDCI .. Proper inspection reduces the llumber of accidents, systcm lo,s and increases the financial activities. The comp,my or tile premises of the industriJ1. eomlll~rcial and domcstic customers have been inspected by certified per~on"ls help to reduce the syMemlo,~. In the financial year, regular inspection and m"intenanc~ system loss has comedown to 6.47% compared to 7.06% in the last year-2006. It is p()ssible only by sincere inspection and maintenance the gas pipeline and it s equipment,. en_US
dc.language.iso en en_US
dc.publisher Department of Petroleum & Mineral Resources Engineering, BUET en_US
dc.subject Gas Transmission en_US
dc.title Inspection, safety and health concerns and practices titas gas transmission and distribution company limited en_US
dc.type Thesis-MSc en_US
dc.contributor.id 100113003 en_US
dc.identifier.accessionNumber 106163
dc.contributor.callno 665.74/SID/2007 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search BUET IR


Advanced Search

Browse

My Account