DSpace Repository

Assessment of post-fire capacity of reinforced concrete beam

Show simple item record

dc.contributor.advisor Ahmed, Dr. Shameem
dc.contributor.author Mehedi Hassan Bhuiyan, Md.
dc.date.accessioned 2025-04-21T06:29:16Z
dc.date.available 2025-04-21T06:29:16Z
dc.date.issued 2024-12-07
dc.identifier.uri http://lib.buet.ac.bd:8080/xmlui/handle/123456789/7058
dc.description.abstract This thesis investigates the post-fire residual capacity of reinforced concrete (RC) beams using a combination of finite element analysis and simplifiedmethods. Following the validation of the finite element model with experimental test data, a comprehensive parametric study was conducted to assess the effects of various key factors on the post-fire flexural capacity of RC beams. The study examined the influence of beam depth (400, 500, 600, and 700 mm), concrete cover thickness (38, 50, and 75 mm), and longitudinal rebar diameter (16, 20, and 25 mm), across different fire exposure durations (30 to 240 minutes), following the ISO 834 fire standard. In total, 36 RC beam specimens were analyzed, resulting in 324 detailed parametric simulations using the finite element software Abaqus. The results from the parametric study demonstrated a significant reduction in post-fire moment capacity with increasing fire exposure duration and higher reinforcement ratios. Simplified methods from the literature and analytical approaches in international standards provided conservative estimates for beams with low reinforcement ratios and shorter fire durations. However, as both reinforcement ratio and fire exposure duration increased, these methods tended to overestimate the post- fire moment capacity. To address this limitation, a modification factor dependent on reinforcement ratio and fire duration was introduced and implemented into the existing simplified approach, which reduced the coefficient of variation in predictions from 0.141 to 0.07 and improved the R-squared value from 0.857 to 0.945. These findings highlight the importance of considering both reinforcement ratio and fire exposure duration in post-fire capacity evaluations. The proposed modifications enhance the reliability of simplified methods, offering engineers a more accurate tool for assessing the residual capacity of fire-damaged RC beams, ultimately improving safety evaluations and structural recovery planning. en_US
dc.language.iso en en_US
dc.publisher Department of Civil Engineering (CE), BUET en_US
dc.subject Reinforced concrete-Structures en_US
dc.title Assessment of post-fire capacity of reinforced concrete beam en_US
dc.type Thesis-MSc en_US
dc.contributor.id 0421042311 en_US
dc.identifier.accessionNumber 119934
dc.contributor.callno 624.183/MEH/2024 en_US